Blocked by Content Security Policy (CSP)

Problem

From PTC Windchill, when you try to link a change request or a part to an ELM artifact, the selection dialog may not be shown. The result depends on the browser:

Solution

When this error happens, it probably means the Windchill server needs to be added to the friends of the target ELM application:

  1. Connect to the ELM application as an administrator (EWM, DOORS Next or ETM depending on your need).
  2. Go the ELM application administration area.
  3. On the left menu, click on the Friends (Outbound) section.
  4. Click add and fill the form with Windchill's rootservices URL.
  5. Don't forget to allow the pending consumer in the Windchill OSLC Connect consumers administration page.
  6. Repeat this procedure for each ELM application involved in your setup.

Check that you don't face the issue anymore and you see the delegated UI instead.